Electronic Timer
Characteristics
- Delay on Energise (DE): The relay energises after set interval of time.
- Interval On (IT): The relay energises immediately and de-energises after set interval of time.
- Cyclic (CY): The relay energises and de-energises in cyclic mode for equal ON and OFF time as per the dial setting.
- Immediate Cyclic (IC): The relay energises immediately for the set ON time and de-energises for the set OFF time in a cycling mode
- Delayed Cyclic (DC): The relay remain de-energises for the set OFF time and energises for the set ON time in a cycling mode
Technical Data
- Supply Voltage tolerance: +-10%
- Power consumption: 5 V A (max)
- Time ranges 1, 2, 5, 10, 30, 60 seconds and 2, 5, 10, 30, 60 minutes and 2, 5, 10, 30, 60 hours
- Repeatability- 1% with fixed off time between runs
- Reset Time- Less than 100ms before timing. 15 ms after timing
- Scale range- 2% to 100%
- Mechanical life- 5 Million operations